Home Scale Packages Products Technical Support Dealer Information Contact Us

TECHNICAL SUPPORT: Avery Weigh-Tronix Troubleshooting Guides

Model Problem Procedure
Model 1015 Won't turn on Check input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys
Model 1015 Won't zero / shows err Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 1015 Stuck on # Check keypad for damaged area. make sure unit is in "gross" mode. Disconnect bars.
Model 1015 Scale isn't weighing right Check bars. Make sure they are showing the same. Check code number in unit.
Model 1015 Shows last ingredient of recipe Needs at least rev. e if not sent in. Do master reset. Need all info. Before doing master reset.
Model 600 Won't turn on Check input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys
Model 600 Won't zero / shows err Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 600 Scale isn't weighing right Check bars. Make sure they are showing the same. Check code number in unit.
Model 615 Won't turn on Check input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys
Model 615 Won't zero / shows err Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 615 Locked on zero 4 bar indicators = with two bars hooked up the applied weight will show up as 2 times the weight on display.
Model 615 Scale isn't weighing right 3 bar units = with one bar hooked up the applied weight will show up as 2 times the weight on the display. 50 x 2 =100
Model 615 Hooking up to rd-4000 / 6000 The RD needs software version 8.0 to run on farm units.
Model 700 Won't turn on Check input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys
Model 700 Won't zero / shows err Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 700 Scale isn't weighing right Check bars. Make sure they are showing the same. Check code number in unit.
Model 700e Won't turn on Check input voltage 10 to 16 volts dc. Must be negative ground system. Check keypad make sure no damage to keys
Model 700e Won't zero / shows err / stuck on # Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 700e Scale isn't weighing right Check bars. Make sure they are showing the same. Check code number in unit.
Model 700e Hooked up to rd-712 Needs the green wire removed in the rd-712 to work correctly.
Model 715 Won't turn on Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 715 Won't zero / shows err / stuck on # Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 715 Scale isn't weighing right Check bars. Make sure they are showing the same. Check code number in unit.
Model 915 Won't turn on Check input voltage 10 to 16 volts DC. Must be negative ground system. Check keypad make sure no damage to keys.
Model 915 Won't zero / shows err / stuck on # Disconnect weigh bars, rezero unit. Hook one bar up and rezero unit. Do this until bad bar appears.
Model 915 Scale isn't weighing right Check bars. Make sure they are showing the same. Check code number in unit.
Model 815 Scale is locked up Check power supply voltages +8,-8.5 volts. Try using course zero pot without bars hooked up.
4-pin bars b-c=240 / c-d=240 / b-d=480 a=shield b= red c=black d=white.
5-pin bars a-c=350 / b-d=350 / a-b=262 / b-c=262 /
c-d=262 / a-d=262
A=red / b=green / c=white / d=black / e=shield
7-pin a =red / b=green / c=white / d=black / e=blue / f=yellow / g=shield  

[^TOP]

SCALE-TEC LTD
16027 Highway 64 East       Anamosa, Iowa 52205       Phone: 319-462-2344